LUCAS GENERATOR (a.k.a. DYNAMO)
It has been said many times that, when Joseph Lucas & Sons. designed the DC dynamo, they did so with neither an excess of copper nor steel.
Just after the turn of the century as motorized transportation was developing, motorists became aware of the dangers of driving about after dark. (The quotation "A gentleman does not motor about after dark." has been attributed to Joseph Lucas, but I cannot confirm if this is true.) Acetylene lamps were mounted on vehicles and served more to warn other motorists of your approaching, and of limited value to see where you were going.
As maximum speeds increased it became necessary to have more efficient lighting. By this time, Thomas Edison (an American) had already invented the electric light bulb which could be powered by a lead/acid battery. The battery was a DC (direct current) device, so now we need a DC generating device to keep the battery charged. No problem says Lucas, and they began manufacturing DC dynamos for the British transportation industry.
The DC voltage generated by a DC dynamo is governed by three factors, and each factor has limitations.
1) Number of turns of wire on the armature.
This value is fixed by the physical size of the armature, and by the
size of the wire. The more turns, the higher the voltage. The
larger the wire, the higher the current.
2) Magnetic field developed in the field coil. This depends
upon the number of turns of wire and the current passing through the wire.
The output voltage will rise until the magnetic saturation of the pole
piece is reached.
A regulator works by increasing and decreasing the current through the field,
depending on rpm of armature and load demand.
3) The rotational speed of the armature, which is governed by the engine
speed.
Generator styles
Although there were a myriad of variations,
the most common styles of generators are as follows-
E3H (short) Rated at 48 watts. Recognized
by having only one screw holding field coil pole shoe.
E3L (long) Rated at 60 watts. Recognized by having
two screws holding field coil pole shoe.
Keep in mind that Lucas generators were designed
and built in England, which has a rather cool climate, and that power output
ratings are nominal. Output ratings might be de-rated 10% for applications
where the generator is mounted to the rear of engine, used in southern temperate
climates, or south of the Mason Dixon line.
What's wrong with my
generator?
Each time the generator begins rotation, it generates a small voltage using the residual magnetism from the last time it ran. This small voltage is then fed to the field coil, which induces more magnetism. The increased magnetism then creates a higher voltage in the armature. Thus the generators literally lifts itself by it's own boot straps. When the desired voltage is reached, the voltage regulator kicks in to control the maximum voltage output.
Possible problems
Although the DC generator is a relatively simple
instrument, there are several things that can go wrong.
Open winding in armature. This test will require a DVM (digital volt meter). Because the windings are connected in series, you must measure the resistance between each adjacent commutator coppers. And because this is a relatively small coil of large diameter wire, you can expect only a fraction of an ohm resistance. You must find the same resistance between each adjacent pair of commutator coppers. If you have an open coil, you will read to total resistance of the remaining coils in series. Look for evidence of overheating and/or thrown solder, as a wire may have become unsoldered from the commutator copper. This is most often caused by overloading the generator, or a defective regulator.
Armature coil shorted to ground. Check for continuity between the commutator copper to armature body. Continuity will indicate a shorted coil. Most commonly caused by overheating and charring of insulation.
Armature coil shorted internally to itself. This can only be detected by a "growler" so you might have to take it to a local armature shop.
Defective field coil. Common problem is overheating due to sticking points on the regulator. The insulation becomes charred and flakes off with time and vibration. Nominal resistance should be around 2.8-3.2 ohms. A visual inspection is a good idea and will require unwrapping some of the fabric wrapping. If there is any visual indication of charring, the field coil should be replaced.
Note- all tests below are done assuming
your electrical system is Positive Earth (ground).
Testing the
generator
Another test (this can be performed with generator mounted on bike)
Flashing the field (this
can be performed with generator mounted on bike)
Because the pole shoe is soft iron, it won't hold the
magnetism for an indefinite amount of time. This is especially important
when using a solid state regulator because they require a generator output
of 0.7 volts in order to initialize.
6 volts or 12 volts ?
Early cycles used the short E3H generator which was
rated at 48 watts (or 8 amps). Around 1950 most manufacturers upgraded
to the longer E3L generator rated at 60 watts (or 10 amps). These
instruments were designed to give full output at approx. 20-25 mph and are
certainly adequate for putting around town. And considering that the
majority of vintage Brit bikes are ridden during daylight hours, lighting
is seldom needed except perhaps for annual safety inspections.
Should I convert to a 12 volt electrical system? The first question I must ask is.... why? Most of the time the reason is to have brighter lights, which I can certainly understand. The standard 6v. tungsten headlight bulb provided by Lucas is 24/36 watts. This means your low beam is 24 watts. In this case we offer an easy solution. A chap in NZ or Aussieland is making a 6v. halogen 36/36 watt bulb that fits into the existing Lucas bulb holder without any modification. Not sure, but believe dealers in Canada stock them.
Most Brit bikes with DC generators are 50's vintage, or earlier. Most are not suitable for high speed freeway cruising (except Vincent, of course). If you do a lot of night riding and feel the overwhelming desire to have a 12 volt electrical system, there are two ways to do it-
Click here to check out the PODtronics DC regulators
for Lucas generators ---->